UL1061 Internal Wiring Electric Cable Conductor PVC Insulated Wire
Product Description:
★ Rated temperature: 80ºC
Rated voltage: 300V
★ Reference Standard: UL Subject 758, UL1581 C22.2 NO.210.2
★ Tinned or bare, stranded or solid copper conductor,30-16 AWG
★ Colour-coded lead free SR-PVC insulation
★ Uniform insulation thickness to ensure easy stripping and cutting
★ Passes UL VW-1 FT1 vertical flame test
★ Application: For internal wiring of electronic and electrical equipment,
protection is required where mechanical damage is possible
Conductor |
Insulation |
Maximum Resistance at 20ºC
Ω/km |
AWG |
No./mm |
Dia.
mm |
Nom. Thick.
mm |
Nom.Dia.
mm |
30 |
7/0.1 |
0.30 |
0.26 |
0.82 |
354 |
28 |
7/0.127 |
0.38 |
0.26 |
0.90 |
223 |
26 |
7/0.16 |
0.48 |
0.26 |
1.00 |
139 |
24 |
11/0.16 |
0.61 |
0.27 |
1.15 |
88.9 |
22 |
17/0.16 |
0.76 |
0.26 |
1.28 |
57.5 |
20 |
26/0.16 |
0.94 |
0.26 |
1.46 |
34.6 |
18 |
41/0.16 |
1.18 |
0.26 |
1.70 |
23.3 |
16 |
26/0.254 |
1.49 |
0.26 |
2.02 |
15.1 |